  Datasheet File OCR Text:
 EXTERNAL
TR100 Series
1 0 0 W AT T S S I N G L E O U T P U T A C / D C G E N E R A L
Features
* * * * * * Wide input voltage 90VAC to 264VAC, 50/60Hz Continuous short circuit protection Output voltage available from 12VDC to 48VDC High efficiency 85% typical Meets EN55022 Class "B", conducted emissions MEPS compliance
Specifications
INPUT
Voltage range Frequency Inrush current Isolation Leakage current 90 to 264Vac 47Hz to 63Hz 100A max @ 264Vac Input to Output 4242Vdc 1.5mA max.
STANDARDS AND APPROVALS
Safety standards NSW office of Fair Trading Certificate of approval NSW19568, EN60950, IEC60950, AS/NZS60950 AS/NZS CISPR 11:2002 Group 1, Class B; Meets EN55022 class "B", conducted Complies with AS/NZS 4417 Parts 1,2,3
C-tick EMI standards RCM
MECHANICAL
Dimensions 70x150x35mm IEC320/C14 Right angle, hollow coaxial plug, 2.5mm inside diameter; 5.5mm, outside diameter; 9.5mm length center positive polarity. 720mm with ferrite core 18AWG/UL1185 AC Inlet Output connector
OUTPUT
Output voltage Voltage set-point Ripple and noise Short circuit protection Over voltage protection Hold-up time Load regulation Line regulation Factory preset, see table (not adjustable) +/-2% (60% load) 1% p-p max Continuous (Auto recovery) Option 20ms typ @ 115Vac +/-2 to +/-4% (20 to 100% load) +/-1% max at full load
DC cord length
Selection Table
MODEL NUMBER
TR100A120-21A11 TR100A150-21A11 TR100A180-21A11 TR100A190-21A11 TR100A240-21A11 TR100A280-21A11 TR100A290-21A11 TR100A300-21A11 TR100A360-21A11
RATED Vnom
12Vdc 15Vdc 18Vdc 19Vdc 24Vdc 28Vdc 29Vdc 30Vdc 36Vdc 48Vdc
OUTPUTCUR RENT
8.3A 6.67A 5.56A 5.21A 4.17A 3.54A 3.41A 3.3A 2.78A 2.08A
MAX POWER
100W 100W 100W 99W 100W 99W 99W 99W 100W 99W
ENVIRONMENTAL
Operating temperature Storage temperature 0C to +40C -20C to +85C
Technical Illustration
TR100A480-21A11
Note: MEPS compliance model number change to eg. TRG100A12-21A11. Available, OCT 2007.
260


▲Up To Search▲   

 
Price & Availability of TR100A150-21A11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X